TM 9-2320-364-20-1
2-14. DDEC III/IV TROUBLESHOOTING (CONT).
Section IV. TROUBLESHOOTING CHARTS (Cont.)
E. FLASH CODE:
14
J1587 CODE:
P110 3 - COOLANT TEMPERATURE CIRCUIT FAILED HIGH (VOLTAGE HIGH)
(BELOW)
OR: P175 3 - OIL TEMPERATURE CIRCUIT FAILED HIGH (VOLTAGE HIGH) (BELOW)
NOTE - This chart is only to be used if:
-
1) All basic mechanical checks and physical inspections have been performed with no problem found; and,
2) Diagnosis of DDEC III/IV was started at step START-1, pg 2-539, and you have now been referred here.
STEP/SEQUENCE
RESULT
WHAT TO DO NEXT
14-1
Code Check
Turn ignition on.
Plug in DDR and determine which
PID 110 - FMI 3
Go to 14-2.
code is present.
PID 175 - FMI 3
Go to 14-3.
14-2
Coolant Temp Sensor
Check
Turn ignition off.
Code 110/4 (or any codes
Go to 14-4.
Disconnect CTS (para 7-69)
except Code 110/3).
and install a jumper between
the CTS connector sockets
Anything except
Go to 14-8.
A and B.
Code 110/4.
Turn ignition on.
Read active codes.
14-3
Oil Temp Sensor
Check
Turn ignition off.
Code 175/4 (or any codes
Go to 14-5.
Disconnect OTS (para 7-70) and
except Code 175/3).
install jumper between OTS
connector sockets A and B.
Anything except
Go to 14-9.
Turn ignition on.
Code 175/4.
Read active codes.
14-4
Check for Short to
+5 Volt Line
Turn ignition off.
Less than or equal to
Signal line (ckt #133) is shorted
Remove jumper wire.
10,000 ohms.
to the engine +5 volt line (ckt
Disconnect the engine harness
#416), and/or (ckt #133) signal
connector at the ECM.
line is shorted to ground, and/or
Read resistance between sockets
sensor return (ckt #452).
P3 (ckt #133) and W1 (ckt #416)
Repair short. Then go to 14-30.
on the engine harness connector.
Greater than 10,000
Go to 14-6.
ohms or open.
|