E1 ENGINE CRANKS BUT WILL NOT START (CONT).
3.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Fuel supply OK.
Continuity test.
No aerated fuel.
STE/ICE-R #91.
Fuel filter OK.
REASON FOR QUESTION
Is continuity measured
POSSIBLE PROBLEMS
between terminals 5 and 7 of
If continuity is not present at
emergency shut-off switch?
Emergency shut-off switch faulty.
switch, switch is faulty and will
TRS out of adjustment.
not allow engine to run.
TRS faulty.
Damaged DDEC pulse wheel.
Damaged DDEC ECM terminals
or connectors.
SRS faulty.
Replace emergency
Open in injector return line.
shut-off switch. (Para
Short in injector return line.
NO
7-27). Verify repair,
DDEC ECM input voltage faulty.
go to Step 13 of this
fault.
YES