Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Allow engine to cool before performing troubleshooting maintenance. If necessary use insulated pads
and gloves. Hot engine components will burn and cause injury to personnel.
VOLTAGE TEST
(1) Disconnect TPS harness
connector MC6.
(2) Set multimeter select switch to
volts dc.
(3) Connect positive (+) multimeter lead
to TPS harness connector MC6,
terminal C.
(4) Connect negative (- ) multimeter lead
-
to TPS harness connector MC6,
terminal A.
(5) Turn ON ENGINE switch
(TM 9-2320-364-10).
(6) Are 4.7 to 5.2 vdc present on wire 952
to wire 916 at TPS harness connector
MC6, terminals C and A.
(a) If 4.7 to 5.2 vdc are
present, turn OFF Engine switch
and go to Step 7 of this Fault.
(b) If more than 5.2 vdc are present,
turn OFF Engine switch and go to
Step 10 of this Fault.
(c) If less than 4.7 vdc are present,
turn OFF Engine switch and go to
Step 3 of this Fault.