Click here to make tpub.com your Home Page

Page Title: VOLTAGE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-20-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Allow engine to cool before performing troubleshooting maintenance. If necessary use insulated pads
and gloves. Hot engine components will burn and cause personnel injury.
VOLTAGE TEST
(1) Remove two screws and heat shield.
(2) Disconnect power harness connector
MC17 with connector remover.
(3) Set multimeter select switch to
volts dc.
(4) Connect positive (+) multimeter lead
to power harness connector MC17,
terminals A, B, E and F.
(5) Connect negative (- ) multimeter lead
-
to a known good ground.
(6) Turn ON ENGINE switch
(TM 9-2320-364-10).
(a) If there are less than 10 vdc
present, turn OFF ENGINE switch
and repair wire 240 or 241
(see schematic Fig 2-3) or notify
DS Maintenance.
(b) If 10 to 14 vdc are present,
wires 240 and 241 are OK. Turn
OFF ENGINE switch and go to
Step 13 of this Fault.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business