TM 9-2320-364-20-1
A4 CODE 35 OIL PRESSURE SENSOR (OPS) SIGNAL VOLTAGE HIGH (CONT).
7.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
CHECK ENGINE light (CEL)
DDR test.
on Page 2-295
comes ON and stays ON.
Wires 530 and 452 are not
REASON FOR QUESTION
open.
Is Code 35 displayed on DDR
OPS connector OK.
OPS OK.
DDEC ECM is suspect.
with all connectors
Wires 416, 530, 439, 241 and
reconnected?
240 not shorted.
POSSIBLE PROBLEMS
DDEC ECM faulty.
If other codes are
displayed, go to Fault
Index (Table 2-16).
NO
If no codes are
displayed, go to
Step 8 of this Fault.
YES
Replace DDEC ECM
(Para 7-56).
Verify repair, go to
Step 8 of this Fault.
8.
KNOWN INFO
TEST OPTIONS
CHECK ENGINE light (CEL)
Verify repair.
Does CEL stay ON longer
comes ON and stays ON.
than five seconds?
Wires 530 and 452 are not
REASON FOR QUESTION
open.
OPS connector OK.
If CEL lights for approximately
OPS OK.
five seconds and then goes
Wires 416, 530, 439, 241 and
OUT after ENGINE switch is
240 not shorted.
turned to ON, Fault has been
DDEC ECM OK.
corrected.
POSSIBLE PROBLEMS
NO
Fault corrected.
YES
Go to Fault Index
2-294
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |