TM 9-2320-364-20-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Allow engine to cool before performing troubleshooting maintenance. If necessary use insulated pads
and gloves. Hot engine components will burn and cause personnel injury.
Use jumperwire only between terminals indicated. Failure to comply may result in damage to DDEC
components or wiring.
NOTE
If no codes appear on DDR, start engine
and run until either the CEL comes ON or
the engine has been running at 120 to 160F
(49 to 71C) for at least one minute at greater
than 1,000 RPM.
DDR TEST
(1) Disconnect TBS harness connector.
(2) Place jumperwire between terminals
B and C at TBS harness connector.
(3) Turn ON ENGINE switch
(TM 9-2320-364-10).
(4) Select MODE 01 (ACTIVE CODES)
on DDR.
(5) Are codes 33 and/or 34 displayed
on DDR.
(a) If code 34 and any other is
displayed on DDR, turn OFF
ENGINE switch and go to Step 4
of this Fault.
(b) If code 33 and any other code
except code 34 is displayed on
DDR, turn OFF ENGINE switch
and go to Step 3 of this Fault.
(6) Remove jumperwire from TBS
harness connector.