TM 9-2320-364-20-1
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
44
Semi-
Air
Check air reservoirs (1) attaching valves (2),
Annual
Reservoirs
lines and connections for mounting looseness,
No. 3 and
leaks, bends, dents and cracks. Replace air
No. 5
reservoir or attaching parts if leaking, or have
bends, dents or cracks that could leak. Tighten
loose parts. Refer to Paras 12-29, 12-31 and
12-36.
45
Semi-
Air
Check air reservoirs (1) attaching valves, lines
Annual
Reservoirs
and connections for mounting looseness, leaks,
No. 2 and
bends, dents and cracks. Replace air reservoir
No. 4
or attaching parts if leaking, or have bends,
dents, or cracks that could leak. Tighten loose
parts. Refer to Paras 12-28, 12-30 and 12-36.
2-39
|