2-9. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
TABLES (CONT).
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
43
Semi-
Self-Guided
Check self-guided coupler (1) for cracks,
Radial wear exceeds
Annual
Coupler
damage, or excessive wear. Replace coupler if
3/16 in. (4.76 mm).
cracked or damaged. If radial wear exceeds
3/16 in. (4.76 mm) total, replace coupler
Washer thickness is less
before next mission. If axial clearance
than 3/16 in. (4.76 mm).
exceeds 1/32 in. (.79 mm), measure thickness
of washer (2). If washer (2) thickness is under
3/16 in. (4.76 mm), replace washer. If washer
thickness is larger than 3/16 in. (4.76 mm),
adjust nut (3). Refer to Para 15-20.
If circumference at worn area of coupler jaw
Circumference at worn
(4) is less than 8-1/2 in. (215.9 mm), replace
area is less than 8-1/4 in.
coupler at next scheduled service. If
(209.6 mm).
circumference is less than 8-1/4 in. (209.6
mm), replace coupler before next mission.
Refer to Para 15-20.
2-38