|
|
TM 9-2320-364-20-1
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Item
Interval
Item to Be
Procedure
Not Mission
No.
Inspected
Capable If:
NOTE
If an air-operated grease gun does not purge
the fitting, use a hand-operated grease gun.
If the part does not purge, remove fitting
and clean, install fitting and grease again. If
part still does not purge, refer to
maintenance task for that component.
When using a grease gun, apply lubricant to
the fitting until clean lubricant squeezes out
of the part being lubricated.
28
Semi-
Double
Lubricate the double cardon joints with GAA
Fittings will not purge
Annual
Cardon
every 1,500 miles (2,414 km) or semiannually,
old lubricant out of
Joints
whichever comes first.
component.
(Axles No. 1,
No. 2 and
No. 5)
29
Semi-
Driveshaft
Do not start engine or move truck when
Annual
and Univer-
anyone is working on or under vehicle. Severe
sal Joints
injury or death to personnel could result.
(all axles)
NOTE
If an air-operated grease gun does not purge
the fitting, use a hand-operated grease gun. If
the part does not purge, remove fitting and
clean, install fitting and grease again. If part
still does not purge, refer to maintenance task
for that component.
2-29
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |