2-9. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
TABLES (CONT).
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Item
Interval
Item to Be
Procedure
Not Mission
No.
Inspected
Capable If:
NOTE
If an air-operated grease gun does not purge
the fitting, use a hand-operated grease gun. If
the part does not purge, remove the fitting and
clean, install fitting and grease again. If part
still does not purge, refer to maintenance task
for that component.
11
Semi-
Steering
Lubricate the steering column, steering linkage
Fittings will not purge
Annual
Column
and front steering gear with GAA (6 fittings)
old lubricant out of
every 1,500 miles (2,414 km) or semiannually,
component.
whichever comes first.