![]() TM 9-2320-363-20-2 
WARNING 
Make sure all air lines and fittings are clear of debris Make sure excess pipe 
sealant compound does not enter air lines or fittings. Failure to do so could 
result in equipment failure and/or injury to personnel. 
Sealant compounds can bum easily, can give off harmful vapors, and are 
harmful to skin and clothing. To avoid injury or death, keep away from open 
fire and use in a well-ventilated area.  If sealant compound gets on skin or 
clothing, wash immediately with soap and water. 
NOTE 
Apply thin coat of sealant compound to all male threads. 
3. 
CONNECT HOSE CONNECTOR (29) ON ELBOW (19) AT PORT MARKED "VENT". 
4. 
CONNECT ELECTRICAL CONNECTOR (30) TO RECEPTACLE (31). 
5. 
CONNECT HOSE CONNECTOR (32) TO ELBOW (21) AT PORT MARKED "SUPPLY". 
6. 
CONNECT HOSE CONNECTOR (33) TO ELBOW (23) AT PORT MARKED "TO AXLES". 
7. 
CONNECT ELECTRICAL CONNECTOR (34) TO PRESSURE TRANSDUCER (12). 
NOTE 
Follow-on Maintenance: 
Connect batteries (page 2-29). 
Start vehicle and perform standard leak test (page 2-24). 
Change 3 4-604.11 
 | 
| 
 