![]() TM 9-2320-363-20-2 
CTIS PNEUMATIC CONTROL UNIT MAINTENANCE (CONT) 
13. 
LUBE 
PREFORMED 
PACKINGS 
ON 
CARTRIDGES (15) AND INSTALL CARTRIDGES 
INTO PCU (13) IN SAME ORDER AS REMOVED. 
14. 
INSTALL GASKET (16) AND MOUNTING PLATE 
(17) WITH RAISED SIDE AGAINST PCU (13) 
AND  SECURE  WITH  SIX  SCREWS  (18). 
TORQUE SCREWS TO 40-45 LB-IN (4-5 N.m). 
WARNING 
Make sure all air lines and fittings 
are clear of debris.  Make sure 
excess pipe sealant compound 
does not enter air lines or fittings. 
Failure to do so could result in 
equipment failure and/or injury 
to personnel. 
Sealant  compounds  can  burn 
easily,  can  give  off  harmful 
vapors, and are harmful to skin 
and clothing. To avoid injury or 
death, keep away from open fire 
and use in a well-ventilated area. 
If sealant compound gets on skin 
or clothing, wash immediately 
with soap and water. 
NOTE 
Apply thin coat of sealant compound to all male threads. 
15. 
INSTALL ELBOW (19) IN PORT MARKED "VENT". 
16. 
INSTALL ADAPTER (20) IN PORT MARKED "SUPPLY". 
17. 
INSTALL ELBOW (21) IN ADAPTER (20). 
18. 
INSTALL ADAPTER (22) IN PORT MARKED "TO AXLES". 
19. 
INSTALL ELBOW (23) IN ADAPTER (22). 
INSTALLATION 
1. 
INSTALL BRACKET (24) AND SECURE WITH SIX RIVETS (25). 
2. 
INSTALL PCU (13) ON BRACKET (24) AND SECURE WITH THREE BOLTS (26), THREE NEW LOCK WASHERS 
(27), AND THREE NUTS (28). 
4-604.10 Change 3 
 | 
| 
 