Click here to make tpub.com your Home Page

Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-363-20-2
CTIS PNEUMATIC CONTROL UNIT MAINTENANCE (CONT)
13.
LUBE
PREFORMED
PACKINGS
ON
CARTRIDGES (15) AND INSTALL CARTRIDGES
INTO PCU (13) IN SAME ORDER AS REMOVED.
14.
INSTALL GASKET (16) AND MOUNTING PLATE
(17) WITH RAISED SIDE AGAINST PCU (13)
AND  SECURE  WITH  SIX  SCREWS  (18).
TORQUE SCREWS TO 40-45 LB-IN (4-5 N.m).
WARNING
Make sure all air lines and fittings
are clear of debris.  Make sure
excess pipe sealant compound
does not enter air lines or fittings.
Failure to do so could result in
equipment failure and/or injury
to personnel.
Sealant  compounds  can  burn
easily,  can  give  off  harmful
vapors, and are harmful to skin
and clothing. To avoid injury or
death, keep away from open fire
and use in a well-ventilated area.
If sealant compound gets on skin
or clothing, wash immediately
with soap and water.
NOTE
Apply thin coat of sealant compound to all male threads.
15.
INSTALL ELBOW (19) IN PORT MARKED "VENT".
16.
INSTALL ADAPTER (20) IN PORT MARKED "SUPPLY".
17.
INSTALL ELBOW (21) IN ADAPTER (20).
18.
INSTALL ADAPTER (22) IN PORT MARKED "TO AXLES".
19.
INSTALL ELBOW (23) IN ADAPTER (22).
INSTALLATION
1.
INSTALL BRACKET (24) AND SECURE WITH SIX RIVETS (25).
2.
INSTALL PCU (13) ON BRACKET (24) AND SECURE WITH THREE BOLTS (26), THREE NEW LOCK WASHERS
(27), AND THREE NUTS (28).
4-604.10 Change 3