TM 9-2320-363-20-2
CTIS PNEUMATIC CONTROL UNIT MAINTENANCE (CONT)
13.
LUBE
PREFORMED
PACKINGS
ON
CARTRIDGES (15) AND INSTALL CARTRIDGES
INTO PCU (13) IN SAME ORDER AS REMOVED.
14.
INSTALL GASKET (16) AND MOUNTING PLATE
(17) WITH RAISED SIDE AGAINST PCU (13)
AND SECURE WITH SIX SCREWS (18).
TORQUE SCREWS TO 40-45 LB-IN (4-5 N.m).
WARNING
Make sure all air lines and fittings
are clear of debris. Make sure
excess pipe sealant compound
does not enter air lines or fittings.
Failure to do so could result in
equipment failure and/or injury
to personnel.
Sealant compounds can burn
easily, can give off harmful
vapors, and are harmful to skin
and clothing. To avoid injury or
death, keep away from open fire
and use in a well-ventilated area.
If sealant compound gets on skin
or clothing, wash immediately
with soap and water.
NOTE
Apply thin coat of sealant compound to all male threads.
15.
INSTALL ELBOW (19) IN PORT MARKED "VENT".
16.
INSTALL ADAPTER (20) IN PORT MARKED "SUPPLY".
17.
INSTALL ELBOW (21) IN ADAPTER (20).
18.
INSTALL ADAPTER (22) IN PORT MARKED "TO AXLES".
19.
INSTALL ELBOW (23) IN ADAPTER (22).
INSTALLATION
1.
INSTALL BRACKET (24) AND SECURE WITH SIX RIVETS (25).
2.
INSTALL PCU (13) ON BRACKET (24) AND SECURE WITH THREE BOLTS (26), THREE NEW LOCK WASHERS
(27), AND THREE NUTS (28).
4-604.10 Change 3
|