TM 9-2320-363-20-2
ASSEMBLY
1.
INSTALL RELIEF VALVE (1).
2.
INSTALL GASKET (2) ON COVER (3).
3.
INSTALL PREFORMED PACKING
(4)
ON
HARNESS CONNECTOR (5).
4.
INSERT HARNESS CONNECTOR (5) THROUGH
HOLE IN COVER (3) AND INSTALL HARNESS
NUT (6).
5.
INSTALL SOLENOID (7) ON EACH SPOOL (8)
AND REMOVE TAGS 6. INSTALL SOLENOID
PROTECTOR (9) ON EACH SOLENOID (7) 7.
INSTALL METAL GASKET (10) WITH PRINTED
SIDE UP ON EACH SOLENOID PROTECTOR (9)
8. INSTALL NUT (11) WITH BEVELED EDGE
DOWN ON EACH SPOOL (8).
9.
APPLY LOCTITE TO THREADS ON PRESSURE
TRANSDUCER (12).
10.
INSTALL
PRESSURE
TRANSDUCER
(12)
ENSURING ELECTRICAL CONNECTOR LOCK
IS ORIENTED OUTWARD. TORQUE TO 16-20
LB-FT (22-27 N.m).
11.
TUCK SOLENOID WIRES NEXT TO SOLENOIDS
(7) AND AWAY FROM RELIEF VALVE (1) WHILE
POSITIONING COVER (3) ON PCU (13).
12.
INSTALL COVER (3) AND SIX SCREWS (14).
TORQUE TO 40-45 LB-IN (4-5 N.m).
Change 3 4-604.9
|