TM 9-2320-363-20-2
AIR HORN AND VALVE REPLACEMENT
This task covers:
a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
Applicable Configuration:
General Safety Instruction s:
M917A1 and M917A1 w/MCS
WARNING
Tools and Special Equipment:
Make sure all air lines and fittings are clear
Tool Kit, SC 5180-90-CL-N26
of debris. Make sure excess pipe sealant
compound does not enter air lines or
Materials/Parts:
fittings. Failure to do so could result in
equipment failure and/or injury to
Nut, Lock (3)
personnel.
Sealant compounds can burn easily, can
Compound, Pipe
Appendix C, Item 8
Sealing
give off harmful vapors, and are harmful to
skin and cl othing. To avoid injury or death,
Tags, Identification
Appendix C, Item 26
keep away from open fire and use in well-
ventilated area. If sealant compound gets
Equipment Condition:
on skin or clothing, wash immediately with
soap and water.
Reference
Condition Description
Page 2-28
Air System Drained
Head Liners Removed
4-567.0 Change 3
|