TM 9-2320-363-20-2
FRONT SERVICE BRAKE RELAY VALVE REPLACEMENT
This task covers:
a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
General Safety Instructions:
WARNING
Tools and Special Equipment:
Make sure all air lines and fittings are clear
*
Tool Kit, SC 5180-90-CL-N26
of debris. Make sure excess pipe sealant
compound does not enter air lines or
Material/Parts:
fittings. Failure to do so could result in
equipment failure and/or injury to
Nut, Lock (2)
personnel.
Sealant compounds can burn easily, can
Compound, Pipe
Appendix C, Item 8
Sealing
give off harmful vapors, and are harmful to
skin and clothing. To avoid injury or death,
Equipment Condition:
keep away from open fire and use in well-
ventilated area. If sealant compound gets
Reference
Condition Description
on skin or clothing, wash immediately with
soap and water.
Page 2-28
Air System Drained
REMOVAL
4-534 Change 3
|