TM 9-2320-363-20-2
INSTALLATION
NOTE
M915A2 only: Mounting bracket is attached to bottom of crossmember, as
shown.
All except M915A2 only: Mounting bracket is attached to top of
crossmember.
1.
INSTALL MOUNTING BRACKET (14), TWO WASHERS (13), TWO SCREWS (12), TWO WASHERS (11), AND
TWO NEW LOCK NUTS (10).
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe
sealant compound does not enter air lines or fittings. Failure to do so could
result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open
fire and use in well-ventilated area. If sealant compound gets on skin or
clothing, wash immediately with soap and water.
2.
COAT PIPE THREADS OF FOUR ELBOWS (8) AND CONNECTOR (9) WITH PIPE SEALANT COMPOUND.
3.
INSTALL FOUR ELBOWS (8) AND CONNECTOR (9) ON RELAY VALVE (3).
4.
INSTALL RELAY VALVE (3), TWO WASHERS (7), TWO SCREWS (6), TWO WASHERS (5), AND TWO NEW
LOCK NUTS (4).
5.
CONNECT THREE TUBES (1) AND FOUR HOSES (2) TO RELAY VALVE (3).
Change 3 4-533
|