TM 9-2320-363-20-2
SECONDARY AIR TANK AND FITTINGS REPLACEMENT
This task covers:
a. Removal
b. Cleaning/inspection
c. Installation
INITIAL SETUP
Applicable Configuration:
General Safety Instructions:
All except M915A2
WARNING
Make sure all air lines and
Tools and Special Equipment:
Tool Kit, SC 5180-90-CL-N26
fittings are clear of debris.
Make sure excess pipe
Materials/Parts:
sealant compound does not
enter air lines or fittings.
Failure to do so could result
Compound, Pipe
in equipment failure and/or
Sealing
injury to personnel.
Sealant compounds can burn
References:
easily, can give off harmful
TM 9-2320-363-10
vapors, and are harmful to
skin and clothing. To avoid
injury or death, keep away
Reference
Condition Description
from open fire and use in
well-ventilated area. If sealant
Page 2-28
Air System Drained
compound gets on skin or
TM 9-2320-363-10
Spare Tire Removed
clothing, wash immediately
with soap and water.
REMOVAL
NOTE
Tag all tubes prior to disconnecting to aid in connecting.
1.
DISCONNECT SIX TUBES (1) AND HOSE (2) FROM AIR TANK (3).
2.
REMOVE TWO LOCK NUTS (4), TWO SCREWS (5), AND AIR TANK (3). DISCARD LOCK NUTS.
4-474 Change 3