TM 9-2320-363-20-2
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant
compound does not enter air lines or fittings. Failure to do so could result in equipment
failure and/or injury to personnel.
Sealant compounds ca n burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in well-ventilated
area. If sealant compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Perform steps 1 and 2 only if fittings have been removed from air tank.
1.
COAT PIPE THREADS OF NEW DRAIN VALVE (1), NEW PRESSURE PROTECT VALVE (2), NEW BUSHING (3),
NEW TEE (4), NEW CONNECTOR (5), NEW PLUG (6), NEW CHECK VALVE (7), AND FOUR NEW ELBOWS (8)
WITH PIPE SEALANT COMPOUND.
2.
INSTALL DRAIN VALVE (1), PRESSURE PROTECT VALVE (2), BUSHING (3), TEE (4), CONNECTOR (5), PLUG
(6), CHECK VALVE (7), AND FOUR ELBOWS (8) IN NEW AIR TANK (9).
3.
INSTALL TWO BRACKETS (10), TWO WASHERS (11), TWO CAPSCREWS (12), TWO WASHERS (13), AND
TWO NEW LOCK NUTS (14).
4.
INSTALL TWO MOUNTING BRACKETS (15), TWO CLAMPS (16), TWO WASHERS (17), AND TWO NEW LOCK
NUTS (18).
5.
INSTALL TWO BRACKETS (19), TWO WASHERS (20), AND TWO NEW LOCK NUTS (21).
6.
INSTALL CABLE (22), TWO WASHERS (23), TWO CAPSCREWS (24), TWO WASHERS (25), AND TWO NEW
LOCK NUTS (26).
7.
INSTALL AIR TANK (9), TWO SCREWS (27), AND TWO NEW LOCK NUTS (28).
8.
CONNECT HOSE (29) AND FOUR TUBES (30) TO AIR TANK (9).
NOTE
Follow-on Maintenance:
Perform standard leak test (page 2-24).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |