TM 9-2320-363-20-2
STE/ICE SHUNT REPLACEMENT (CONT)
CLEANING/INSPECTION
Clean and inspect all parts in accordance with Chapter 2.
INSTALLATION
1.
INSTALL STE/ICE SHUNT (1), TWO WASHERS (2), TWO SCREWS (3), TWO WASHERS (4), AND TWO NEW
LOCK NUTS (5) ON FRAME RAIL (6).
2.
INSTALL TWO WIRES (7) AND TWO SCREWS (8) ON STE/ICE SHUNT (1).
3.
INSTALL THREE CABLES (9), TWO WIRES (10), TWO NEW LOCK WASHERS (11), AND TWO SCREWS (12).
NOTE
Follow-on Maintenance:
Connect batteries (page 2-29).
4-264.2 Change 3
|