STE/ICE SHUNT REPLACEMENT
This task covers:
a. Removal
b. Cleaning/Inspection c. Installation
INITIAL SETUP
Personnel Required: (2)
Applicable Configuration:
All except M917A1 and M917A1 w/MCS
Equipment Condition:
Tools and Special Equipment
Reference
Condition Description
Tool Kit, SC 5180-90-CL-N26
Page 2-29
Batteries Disconnected
Materials/Parts:
Nut, Lock (2)
Washer, Lock (2)
REMOVAL
NOTE
Tag all wires and cables prior to removal to aid in installation.
1.
REMOVE TWO SCREWS (1) AND TWO WIRES (2).
2.
REMOVE TWO SCREWS (3), TWO LOCK WASHERS (4), AND THREE CABLES (5) FROM STE/ICE SHUNT (6).
DISCARD LOCK WASHERS.
3.
REMOVE TWO LOCK NUTS (7), TWO WASHERS (8), TWO SCREWS (9), TWO WASHERS (10), AND STE/ICE
SHUNT (6) FROM FRAME RAIL (11). DISCARD LOCK NUTS.
Change 3 4-263