![]() TM 9-2320-363-20-2 
WATER LEVEL PROBE REPLACEMENT 
This task covers: 
a. Removal 
b. Cleaning/Inspection 
c. Installation 
INITIAL SETUP 
Tools and Special Equipment: 
References: 
Tool Kit, SC 5180-90-CL-N26 
TM 9-2320-363-20-1 
Materials/Parts: 
Equipment Condition: 
Washer, Lock (2) 
(M915A2 and M916A1) 
Reference 
Condition Description 
Compound, Pipe 
Appendix C, Item 8 
Cooling System Drained 
Sealing 
Page 2-29 
Batteries Disconnected 
REMOVAL 
NOTE 
Perform step 1 for M915A2 and M916A1. 
1. 
REMOVE SCREW (1), LOCK WASHER (2), NUT (3), AND LOCK WASHER (4) AND DISCONNECT TWO WIRES 
(5) FROM PROBE (6). DISCARD LOCK WASHERS. 
NOTE 
Perform step 2 for all except M915A2 and M916A1 
2. 
DISCONNECT CONNECTOR (7) FROM PROBE (6). 
3. 
REMOVE PROBE (6) AND BUSHING (8) FROM RADIATOR (9). 
CLEANING/INSPECTION 
Clean and inspect all parts in accordance with Chapter 2. 
 | 
| 
 