TM 9-2320-363-20-2
WATER LEVEL PROBE REPLACEMENT
This task covers:
a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
Tools and Special Equipment:
References:
Tool Kit, SC 5180-90-CL-N26
TM 9-2320-363-20-1
Materials/Parts:
Equipment Condition:
Washer, Lock (2)
(M915A2 and M916A1)
Reference
Condition Description
Compound, Pipe
Appendix C, Item 8
Cooling System Drained
Sealing
Page 2-29
Batteries Disconnected
REMOVAL
NOTE
Perform step 1 for M915A2 and M916A1.
1.
REMOVE SCREW (1), LOCK WASHER (2), NUT (3), AND LOCK WASHER (4) AND DISCONNECT TWO WIRES
(5) FROM PROBE (6). DISCARD LOCK WASHERS.
NOTE
Perform step 2 for all except M915A2 and M916A1
2.
DISCONNECT CONNECTOR (7) FROM PROBE (6).
3.
REMOVE PROBE (6) AND BUSHING (8) FROM RADIATOR (9).
CLEANING/INSPECTION
Clean and inspect all parts in accordance with Chapter 2.
|