1.
INSTALL AIR RESTRICTION INDICATOR (1) AND TWO SCREWS (2) IN PANEL (3).
2.
INSTALL LIGHT (4), WASHER (5), NUT (6), SWITCH (7), PIGTAIL (8), AND TWO SCREWS (9).
3.
INSTALL TWO AIR VENTS (10), TACHOGRAPH (11), TWO BRACKETS (12), AND TWO NUTS (13).
4.
INSTALL TWO SWITCHES (14), TWO NUTS (15), AND THREE LABEL HOLDERS (16).
WARNING
Make sure all air lines and fittings are clear of debris.  Make sure excess pipe
sealant compound does not enter air lines or fittings. Failure to do so could result
in equipment failure and/or injury to personnel.
5.
COAT THREADS WITH PIPE SEALANT COMPOUND AND INSTALL TWO ELBOWS (17) IN VALVE (18 ).
6.
INSTALL VALVE (18), GUARD (19), AND TWO SCREWS (20) IN PANEL (3).
7.
INSTALL THREE FIBER OPTIC LABELS (21).
8.
CONNECT TWO CABLES (22), TWO CONNECTORS (23), THREE PLUGS (24), AND THREE TUBES (25) TO
BACK OF PANEL (3).
9.
INSTALL PANEL (3), FIVE SCREWS (26), DASHBOARD TOP COVER (27), AND SIX SCREWS (28).
NOTE
Follow-on Maintenance:
Connect batteries (page 2-29).