28-5. AUXILIARY WINCH REPAIR (CONT)
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use
only with effective chip guarding and personal protective equipment (goggles,
shield, and gloves).
(2)
Dry parts with compressed air.
(3)
Clean all sealing surfaces.
(4)
Inspect machined surfaces for damage.
(5)
Replace oil seals and damaged parts.
(6)
Inspect bushing and bearings for pitting, roundness, and for inside diameter larger than 5/8 in. (16 mm).
(7)
Replace bushing or bearings if pitted, out of round, or smaller than 5/8 in. (16 mm).
c.
Assembly
NOTE
Do steps (1) and (2) if bushing and
bearings were removed.
(1) Press bronze bushing (1) into end cover (2).
(2) Press two bronze bearings (3) into ends of drum
(4).