TM 9-2320-360-34-2
28-4. HYDRAULIC PUMP REPAIR (CONT)
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use
only with effective chip guarding and personal protective equipment (goggles,
shield, and gloves).
(2) Dry parts, except bearings, with compressed air.
(3) Inspect parts for cracks, chipping, and warping. If damage is found, replace parts:
c.
Assembly
NOTE
Ensure directional plug is in correct
hole as shown.
(1) Install plug (1) in shaft end cover (2).
WARNING
On direct contact, uncured silicone
sealant Irritates eyes.
In case of
contact, flush eyes with water and
seek medical attention. In case of
skin contact, wipe off and flush with
water.
(2) Coat outside edge of new seal (3) with silicone
adhesive-sealant.
(3) Install new seal (3) metal side up in back of shaft
end cover (2).
(4) Install new sealed bearing (4) in back of shaft
end cover (2).
(5) Install new retaining ring (5) in back of shaft end
cover (2).
NOTE
Notched side
of
ring
seals
face
bearings.
(6) Install new ring seal (6) in shaft end cover (2).
(7) Install two bearings (7) in shaft end cover (2).
28-44
|