TM 9-2320-360-34-2
(30) Remove two studs (44) from shaft end cover
(37).
(31) Remove two bearings (45) and ring seal (46)
from shaft end cover (37). Discard ring seal.
(32) Remove retaining ring (47) from back of shaft
end cover (37). Discard retaining ring.
(33) Remove seated bearing (48) from shaft end
cover (37). Discard sealed bearing.
(34) Remove seal (49) from shaft end cover (37).
Discard seal.
(35) Remove plug (50) from shaft end cover (37).
b. Cleaning/Inspection
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and don't breathe vapors. Do not use near open flame or excessive heat.
The flash point is 100-138 F (38-59 C). If you become dizzy while using cleaning
solvent, get fresh air immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
(1) Clean metal parts in dry cleaning solvent.
28-43
|