TM 9-2320-360-34-2
e.
Installation
CAUTION
Keep seal ring sealed in package
until ready to use so seal ring does
not change shape.
(1)
Compress new seal ring (1) to one-half
diameter and hold for at least 10 seconds.
(2)
Install new seal ring (1) in groove on
torque converter pump hub (2).
CAUTION
Make sure tangs of converter hub
engage properly in transmission
pump. Failure to comply may result
in damage to equipment.
(3)
Install torque converter pump (3) in torque
converter housing (4).
(4)
Position driver handle tool (5) around
ground sleeve (6) and on pump (3). Drive
pump down until seated.
(5)
Remove driver handle tool (5).
(6)
Install spacer (7) over ground sleeve (6)
and in pump (3).
WARNING
Wear eye protection and use care
when installing retaining rings.
Retaining rings are under spring
tension and can act as projectiles
when released causing severe eye
injury.
(7)
Using snap ring remover/installer (8),
install retaining ring (9) on ground sleeve
(6).
(8)
Coat pump (3) and area around hub ( )
2
with lubricating oil.
f.
Follow-On Maintenance
Install torque converter stator (para 22-5).
22-23
|