TM 9-2320-360-34-2
22-6. TORQUE CONVERTER PUMP REPAIR
This task covers:
a. Removal
d.
Assembly
b. Disassembly
e.
Installation
c. Cleaning/Inspection
f.
Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Materials/Parts
Torque converter stator removed (para 22-5).
Oil, Lubricating (Item 44, Appendix B)
Solvent, Dry Cleaning (Item 54, Appendix B)
Lockstrips (6) (Item 105, Appendix F)
Tools and Special Tools
Tool Kit, Genl Mech (Item 202, Appendix E)
Ring, Retaining (Item 243, Appendix F)
Puller, Bridge (Item 122, Appendix E)
Rings, Seal (Item 252, Appendix F)
Bolts, Puller (2) (Item 10, Appendix E)
Rings, Seal (Item 254, Appendix F)
Compressor Unit, Air (Item 24, Appendix E)
Handle, Driver (Item 67, Appendix E)
Personnel Required
Goggles, Industrial (Item 57, Appendix E)
Two
Remover/installer, Converter Pump Snap
Ring (Item 132, Appendix E)
Screw, Forcing (Item 152, Appendix E)
Sleeve, Puller (Item 159, Appendix E)
Wrench, Torque, 0-175 Lb-Ft (Item 236, Appendix E)
a.
Removal
(1) Turn transmission assembly so torque
converter housing (1) faces up.
WARNING
Wear eye protection and use care
when removing retaining rings.
Retaining tings are under spring
tension and can act as projectiles
when released causing severe eye
injury.
(2)
Remove retaining ring (2) from ground
sleeve (3) with snap ring remover/installer
(4).
Remove spacer (5).
Discard
retaining ring.
(3)
Bend comers of two lockstrips (6) away
from heads of two opposing screws (7).
Remove two screws with aid of assistant.
22-20
|