TM 9-2320-360-34-1
c.
Cleaning/Inspection
(1)
Clean old gasket material from housing and caps.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and don't breathe vapors. DO NOT use near open flame or excessive heat.
The flash point is 100-138° F (38-59° C). It you become dizzy while using cleaning
solvent, get fresh air immediately and medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
(2)
Clean sealant residue from threaded holes with dry cleaning solvent.
(3)
Clean all metal parts with dry cleaning solvent.
WARNING
Compressed air for cleaning purposes will not exceed 30 psi (207 kPa). Use only
with effective chip guarding and personnel protective equipment (goggles/shield,
gloves, etc.).
(4)
Dry all parts except bearings with compressed air. Allow bearings to air dry.
(5)
Remove all small nicks or burrs with crocus cloth.
(6)
Coat all parts with light coat of lubricating oil.
(7)
Inspect housing and caps for damage.
(8)
Inspect all parts with machined surfaces for deep scratches or wear grooves.
(9)
Replace all damaged parts.
d.
Assembly
WARNING
Adhesive-sealant can burn easily,
can give off harmful vapors, and is
harmful to skin and clothing. To
avoid injury or death, keep adhesive-
sealant away from open fire and use
in well-ventilated area. If adhesive-
sealant gets on skin or clothing,
wash immediately with soap and
water.
(1)
Coat inside surface of seal race (1) and
spindle ring (3) with adhesive-sealant.
(2)
Install seal race (1) on spindle (2) if
removed.
(3)
Install spindle ring (3) on spindle (2).
Change 1 10-43
|