6.
Insert wires into the prepared splice barrel and crimp to secure the wires.
Use crimp tool matching the size of the barrel.
7.
Slide the sleeve or tubing over the splice or use tape to insulate the
conductor.
Apply heat to shrink tubing.
Ends of nonshrink sleeve must be tied.
8.
Record the BDAR action taken.
When mission is completed, as soon as
practicable, repair using standard maintenance procedures.
Option 3:
Different Size Wire Splices.
1.
Strip broken wire ends,
stripping enough insulation to allow the smaller wire
to be doubled as shown.
2.
Slide plastic sleeve or shrink tubing,
if available, over one end of broken
wire.
3.
Connect wires by using a splice or terminal lug prepared as in Option 2.
4.
Crimp splice or lug to secure the wires.
5.
Slide the sleeve or tubing over the splice or use tape to insulate the
conductor.
6.
Record the BDAR action taken. When the mission is completed, as soon as
practicable, repair using standard maintenance procedures.
8-13
|