Click here to make tpub.com your Home Page

Page Title: PTO Switch ON Lamp Circuit - Test
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-312-24-2
Troubleshooting Section
Repair: Perform the following diagnostic
I. While the status of the Remote PTO Resume
procedure:
Switch is being observed on ET, install the
jumper into the breakout T in order to connect
1. Temporarily connect a test ECM.
terminal 60 (input 3) to terminal 3 (input sensor
common #2). Also, while the switch status is
2. Ensure that the "PTO Configuration" of the test
being observed on ET remove the jumper from
ECM matches the "PTO Configuration" of the
the breakout T in order to disconnect terminal 60
suspect ECM.
(input 3) from terminal 3 (input sensor common
#2).
3. Remove all jumpers and replace all connectors.
The input 2 is the set switch for the PTO and the
4. Recheck the system for Active diagnostic
input 3 is the resume switch for the PTO.
codes.
Refer to Illustration 158.
5. Repeat the test step.
Expected Result:
6. If the problem is resolved with the test ECM,
reconnect the suspect ECM.
The switch status of the Remote PTO Set Switch on
ET behaves in the following manner:
7. If the problem returns with the suspect ECM,
The switch status of the Remote PTO Set Switch
replace the ECM.
is "OFF" when the jumper is removed.
8. Verify that the repair eliminates the problem.
The switch status of the Remote PTO Set Switch
STOP.
changes from "OFF" to set switch "ON" when the
jumper is connected from terminal 58 (input 2) to
terminal 3 (input sensor common #2).
i01613057
PTO Switch ON Lamp Circuit
The switch status of the Remote PTO Resume
Switch on ET behaves in the following manner:
- Test
The switch status of the Remote PTO Resume
SMCS Code: 7431-081
Switch is "OFF" when the jumper is removed.
System Operation Description:
The switch status of the Remote PTO Resume
Switch changes from "OFF" to resume switch
Use this procedure under the following situation:
"ON" when the jumper is connected from terminal
60 (input 3) to terminal 3 (input sensor common
Use the following information in order to determine
#2).
if the PTO Switch ON Lamp is operating incorrectly.
Results:
Terminal 30 (Output 1)
Yes The input 2 (Remote PTO Set Switch) and
Output 1 can be used as a PTO Switch On Lamp
the input 3 (Remote PTO Resume Switch) of the
output. If the "PTO Configuration" is programmed
ECM are functioning correctly. The problem is in
to "Cab Switches", "Remote Switches", or "Remote
the switches of the vehicle or the problem is in
Throttle", the output will turn on the lamp whenever
the wiring of the vehicle.
the PTO Switch Circuit is turned on.
Repair: Inspect the wiring. Select one of the
Electrical Connection of Lamps
following options:
One terminal of the lamp must be connected to
Repair the wiring or replace the wiring.
battery voltage through the vehicle wiring. The other
terminal is connected to the ECM at the vehicle
Send the vehicle to the OEM dealer for repair.
harness connector J1/P1 at terminal 30.
Verify that the repair eliminates the problem.
The ECM provides a path to ground in order to turn
on the lamp.
STOP.
No The ECM is not reading the switch status
change.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business