TM 9-2320-312-24-1
AC COMPRESSOR REPLACEMENT - CONTINUED
0155 00
REMOVAL
1.
Remove nut (1), screw (2), relay (3), and ground wires (5) from bracket (6) on right side of frame.
2.
Disconnect relay connector (8) from relay (3).
3.
Remove compressor wire (4) from relay connector (8) (WP 0120 00).
4.
Remove tiedown straps from compressor wire (4) and discard. Remove wire loom (7) from compressor wire.
1,2
4
4
3
3
8
7
6
5
CAUTION
Water and dirt can damage refrigerant system. Refrigerant lines should be capped after disconnection to
avoid contamination.
Use two wrenches when loosening fitting nuts to avoid twisting tubes.
NOTE
Tag AC compressor hoses to ensure correct installation.
Refer to WP 0156 00 for instructions on properly disconnecting/connecting AC lines.
5.
Disconnect two AC hoses (16) from AC compressor (15).
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Failure to follow this warning may result in injury to personnel.
0155 00-2
|