AC CONDENSER REPLACEMENT - CONTINUED
0152 00
INSTALLATION - CONTINUED
NOTE
Apply refrigerant oil to preformed packings of condenser hoses before they are connected. DO NOT reuse
preformed packings.
3.
Connect two hoses (9) to side of condenser (5) and tighten two fitting nuts (10).
4.
Install bottom recirculation shield (1) to two side recirculation shields (2) with eight screws (4) and nuts (3).
1
2
3,4
NOTE
Any time air conditioning system refrigerant is evacuated, replace receiver-drier.
5.
Replace receiver-drier (WP 0154 00).
6.
Place battery disconnect switch in ON position.
7.
Charge air conditioning system (WP 0149 00).
8.
Leak test air conditioning system (WP 0057 00).
9.
Lower cab (TM 9-2320-312-10).
END OF WORK PACKAGE