TM 9-2320-312-24-1
AC CONDENSER REPLACEMENT - CONTINUED
0152 00
REMOVAL - CONTINUED
CAUTION
Water and dirt can damage refrigerant system. Refrigerant lines should be capped after disconnection to
Use two wrenches when loosening fitting nuts to avoid twisting tubes of condenser.
NOTE
Tag condenser hoses to ensure correct installation.
Refer to WP 0156 00 for instructions on properly disconnecting/connecting AC lines.
2.
Loosen fitting nuts (10) and disconnect two hoses (9) from side of condenser (5).
3.
Remove six nuts (7), screws (8), and condenser (5) with two angle brackets (6) from side recirculation shields (2).
4.
Remove six locknuts (11) and screws (12) and separate condenser (5) from two angle brackets (6). Discard locknuts.
5
6
2
11,12
7,8
9
10
INSTALLATION
1.
Install condenser (5) to two angle brackets (6) with six screws (12) and new locknuts (11).
2.
Position condenser (5) with two angle brackets (6) to side recirculation shields (2) and install six screws (8) and nuts (7).
0152 00-2