TM 9-2320-312-24-1
CAB TILT HYDRAULIC SYSTEM FILLING AND BLEEDING - CONTINUED
0125 00
FILLING AND BLEEDING
WARNING
When servicing this vehicle, performing maintenance, or disposing of materials such as engine coolant,
transmission fluid, lubricants, battery acids or batteries, consult your unit/local hazardous waste disposal
center or safety office for local regulatory guidance. If further information is needed, please contact The
Army Environmental Hotline at 1-800-872-3845.
CAUTION
Wipe area clean around filler plug opening prior to removing plug. Cap or plug opening after removing plug.
Contamination of hydraulic system could result in equipment failure.
NOTE
Rotate pump handle socket at top of cab tilt pump for access to filler plug.
1.
Remove filler plug (1) from top of cab tilt pump (2).
2.
Fill cab tilt pump (2) to within in (12.7 mm) of top surface of pump. Loosely install filler plug (1).
1
2
NOTE
If cab stops in a partially tilted position, release cab tilt button.
Tilting and lowering cab will bleed air from cab tilt hydraulic system.
3.
Tilt cab (TM 9-2320-312-10) to fully tilted position or as far as cab will tilt. Lower cab (TM 9-2320-312-10).
4.
Repeat step 3.
5.
Remove filler plug (1) and check fluid level in cab tilt pump (2) by inserting a "dipstick" down through filler opening
until it touches bottom. Level should be approximately in (6.4 mm) to in (12.7 mm) on "dipstick".
6.
Add hydraulic fluid, as necessary, and repeat steps 3 through 5.
7.
When fluid level has stabilized at correct level (step 5), install and tighten filler plug (1).
END OF WORK PACKAGE
0125 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |