TM 9-2320-312-24-1
CAB TILT PUMP ASSEMBLY MAINTENANCE - CONTINUED
0124 00
CIRCUIT BREAKER REMOVAL
NOTE
Tag wires to ensure correct installation.
Remove tiedown straps as needed and discard. Use new tiedown straps on installation.
1.
Open pump box (2).
2.
Remove two screws (25), lockwashers (26), and locknuts (27) to separate circuit breaker (21) from side of pump box
(2). Discard locknuts and lockwashers.
NOTE
Replacement circuit breaker comes with new attaching hardware for wires.
3.
Remove two screws (22) and lockwashers (23) to disconnect wire (19) and wire (24) from rear of circuit breaker (21).
21
22,23
2
19
25,26,27
24
CIRCUIT BREAKER INSTALLATION
1.
Connect wire (19) and wire (24) to rear of circuit breaker (21) with two new lockwashers (23) and screws (22).
2.
Install circuit breaker (21) to side of pump box (2) with two screws (25), new lockwashers (26), and new locknuts (27).
3.
Close pump box (2).
4.
Place battery disconnect switch in ON position.
END OF WORK PACKAGE