TM 9-2320-312-24-1
CAB TILT PUMP ASSEMBLY MAINTENANCE - CONTINUED
0124 00
RELAY REMOVAL
NOTE
Tag wires to ensure correct installation.
Remove tiedown straps as needed and discard. Use new tiedown straps on installation.
1.
Open pump box (2).
2.
Remove two locknuts (15) and lockwashers (16) to separate relay (14) from two studs of pump box (2). Discard lock-
nuts and lockwashers.
NOTE
Replacement relay comes with new attaching hardware for wires.
3.
Remove two nuts (17) and screws (18) to disconnect three wires (19) from bottom of relay (14).
4.
Disconnect connector (20) from relay (14).
15,16
14
2
2
17,18
20
17,18
19
RELAY INSTALLATION
1.
Connect connector (20) to bottom of relay (14).
2.
Connect three wires (19) to relay (14) with two screws (18) and nuts (17).
3.
Install relay (14) to two studs of pump box (2) with two new lockwashers (16) and new locknuts (15).
4.
Close pump box (2).
5.
Place battery disconnect switch in ON position.
0124 00-7
|