CAPACITOR AND CAPACITOR START RELAY REPLACEMENT - CONTINUED
0119 00
RELAY REMOVAL
1.
Remove two batteries from top shelf of battery box (WP 0114 00).
2.
Remove two nuts (12), washers (13), and disconnect two cables (2 and 16) and electrical lead (11) from terminals of
relay (17). Disconnect electrical lead (18) from relay.
3.
Remove four nuts (14), screws (15), and relay (17) from battery box.
12,13
2
16
14,15
11
18
17
RELAY INSTALLATION
1.
Install relay (17) to battery box with four screws (15) and nuts (14).
2.
Connect electrical lead (18) to relay (17). Connect electrical lead (11) and cables (2 and 16) to terminals of relay with
two washers (13) and nuts (12).
3.
Install two batteries to top shelf of battery box (WP 0114 00).
4.
Connect battery cables (WP 0115 00).
5.
Apply one or more coats of insulating varnish to relay electrical connections.
END OF WORK PACKAGE