ETHER COLD START SYSTEM MAINTENANCE - CONTINUED
0077 00
SOLENOID VALVE REMOVAL
WARNING
Ether fuel is extremely flammable and toxic. DO NOT smoke and make sure you are in a well-ventilated
area away from heat, open flames or sparks. Wear eye protection. Avoid contact with skin and eyes and
avoid breathing ether fumes. If fluid enters or fumes irritate the eyes, wash immediately with large quantities
of clean water for 15 minutes. Seek medical attention immediately if ether is inhaled or causes eye irritation.
Failure to follow this warning may cause death or serious injury to personnel.
1.
Remove left-front mudflap (WP 0048 00).
2.
Remove ether cylinder (Refer to Ether Cylinder Removal).
3.
Disconnect two relay harness connectors (8) from ether cold start system harness connectors (9).
4.
Disconnect connector (15) from 1A fuse holder (16).
5.
Disconnect solenoid valve connector (14) from ether cold start system harness connector (13).
16
15
13
14
9
8
0077 00-6