TM 9-2320-304-14&P
5-229
Direct Support and General Support Maintenance (Cont)
NOTE
Right side shown. Left side drilled the same as right side.
(7) Drill one 0.562-in. (14.3 mm) hole (9) 1.97 in. (50 mm) down from top and 2 in. (50.8 mm) in
from back on right side of stowage box (10).
(8) Drill one 0.562-in. (14.3 mm) hole (11) 4.97 in. (126.2 mm) down from top and 2 in. (50.8 mm) in
from back on right side of stowage box (10).
(9) Repeat steps (7) and (8) for left side of stowage box.
NOTE
Enlarge screw holes in rear panel of stowage box only. Do not enlarge holes through rear
stowage box lower reinforcement.
(10) Ream two existing holes (12) in rear panel of stowage box to 1.75 in. (44.5 mm).
Change 1
|