TM 9-2320-304-14&P
4-153
Organizational Maintenance Instructions (Cont)
b. Type 2 Connector Repair.
CAUTION
Terminals come in different styles and
sizes. To prevent damage, be sure to use
only the exact replacements. Do not
attempt to modify terminal to fit.
NOTE
Repeat procedure as necessary.
(1) Disassembly.
(a) Remove two screws (1) and cable
clamp (2) from connector (3).
(b) Remove heat shrink (4).
(c) Remove wire (5) and terminal (6)
from connector (3).
NOTE
Cut as close to damaged terminal as
possible.
(d) Cut off terminal (6) at end of
wire (5). Remove insulation (7) 1/4
inch (.635 cm) from end of wire (3).
Discard terminal.
(2) Assembly.
(a) Install terminal (1) on
connector (2).
(b) Install cable clamp (3) on
connector (2) with two screws (4).
(c) Install heat shrink (5) around
wires (6).
|