Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-60
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
8. REVERSE ALARM DOES NOT OPERATE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 3. With light switch in service drive position, check for 22 to 28 Vdc on wire 1665A at reverse
alarm switch terminals, with transmission range selector in R (Reverse).
If Vdc measurement is within specification on one terminal and 0 Vdc is measured
on other terminal, replace reverse alarm switch (Para 4-45).
If Vdc measurement is below specification on both terminals, go to Step 4. of this
fault
|