Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-59
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
8. REVERSE ALARM DOES NOT OPERATE.
NOTE
For Fault 8 the engine must be running.
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 1. Check for continuity on wires 1435 at reverse alarm and chassis ground.
If there is no continuity, repair wire 1435 or notify DS Maintenance.
Step 2. With light switch in service drive position, check for 22 to 28 Vdc on wire 1665A at reverse
alarm, with transmission range selector in R (Reverse).
If Vdc measurement is within specification, replace reverse alarm (Para 4-44).
If Vdc measurement is below specification, go to Step 3. of this fault.
|