Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-61
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
8. REVERSE ALARM DOES NOT OPERATE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 4. With light switch in service drive position, check for 22 to 28 Vdc on wire 1665A at splice to
MILITARY CONNECTOR wire 665.
If Vdc measurement is below specification, repair wire 1665A, the splice, or notify
DS Maintenance.
Step 5. Check operation of reverse alarm.
If reverse alarm does not operate, fault is not corrected. Notify DS Maintenance.
|