Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-58
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
7. LHS CIRCUIT BREAKER DOES NOT OPERATE.
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 1. Check for 22 to 28 Vdc on both sides of circuit breaker.
If Vdc measurement is below specification, replace circuit breaker (Para 4-33).
|