Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-57
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
6. LOSS OF SUPPLY VOLTAGE TO MAIN JUNCTION BOX (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 2. Check for loss of voltage to distribution box.
Refer to Fault 5.
Step 3. Check for 22 to 28 Vdc at terminal 9 of main junction box terminal.
If Vdc measurement is below specification, replace LHS distribution box (Para 4-34).
|