TM 9-2320-303-24-2
AIR CONDITIONER CONDENSER REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Materials/Parts
Maintenance Level
Adhesive, loctite (Item 3, WP 0312 00)
Direct Support
Cap set (Item 8, WP 0312 00)
Tools and Special Tools
Oil, refrigerant (Item 34, WP 0312 00)
Tool kit, general mechanic's (Item 102, WP 0313
Rags, wiping (Item 39, WP 0312 00)
Tags, marker (Item 42, WP 0312 00)
Crowfoot attachment set (Item 16, WP 0313 00)
References
Gloves, protective (Item 28, WP 0313 00)
WP 0218 00
Goggles (Item 30, WP 0313 00)
Wrench, torque, 0-300 lb-in (Item 109, WP 0313
Equipment Condition
Wrench, torque, 15-75 lb-ft (Item 110, WP 0313
Refrigerant recovered (WP 0297 00)
WARNING
Use care to prevent refrigerant from touching your skin or eyes. Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye tissue. Serious injury or blindness may result if you come
in contact with liquid refrigerant.
Refrigerant R-134a air conditioning systems should not be pressure tested or leak tested with com-
pressed air. Combustible mixtures of air and R-134a may form, resulting in a fire or explosion, which
could cause personnel injury or death.
REMOVAL
CAUTION
Water and dirt can damage refrigerant system. Five minutes of not being capped is the limit for any hose or
component. DO NOT blow shop air through refrigerant hoses. Shop air is wet (humid).
NOTE
DO NOT disconnect refrigerant fittings using only one wrench. Hold one fitting in place using a wrench and
turn other fitting with a second wrench.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |