Click here to make tpub.com your Home Page

Page Title: REMOVAL - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-303-24-2
AIR CONDITIONER CONDENSER REPLACEMENT - CONTINUED
0304 00
REMOVAL - CONTINUED
1.
Tag and disconnect refrigerant lines (1) from condenser (2). Install plugs in refrigerant and condenser lines.
2.
Remove fasteners attaching condenser (2) to radiator.
1
2
INSTALLATION
1.
Position condenser (2) on radiator and install fasteners.
2.
Remove plugs from refrigerant lines (1) and line ports on new condenser (2).
3.
Install new preformed packings and apply refrigerant oil to preformed packings.
4.
Apply loctite to male fitting threads and connect but do not tighten refrigerant lines (1) to condenser (2).
NOTE
DO NOT connect refrigerant fittings using only one wrench. Hold one fitting in place using a wrench and
turn other fitting with a second wrench.
5.
Tighten connections in accordance with WP 0311 00.
6.
Service air conditioner compressor (WP 0301 00).
7.
Charge air conditioning system (WP 0297 00).
0304 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us