Table 5. Problem - Compressor Operates Too Often or Continuously.
Possible Cause
Remedy
There is too little refrigerant in system.
Repair any leaks (WP 0305 00) and add a full charge of refrigerant (WP 0297 00).
There is a restriction in refrigerant system. Remove restriction from line.
Table 6. Problem - Quick or Delayed Cycling of Compressor.
Possible Cause
Remedy
Loss of refrigerant is causing a delayed Add a full charge of refrigerant (WP 0297 00).