TM 9-2320-303-24-1
PRIMARY I AIR TANK AND FITTINGS REPLACEMENT - CONTINUED
0129 00
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.
NOTE
Perform steps 1 through 3 only if fittings have been removed from air tank.
Install automatic drain valve (WP 0133 00) if equipped.
1.
Coat pipe threads of two new plugs (6), new drain valve (11), new check valve (7), and two new elbows (9) with pipe
sealant compound.
2.
Install two plugs (6), drain valve (11), check valve (7), and two elbows (9) in new air tank (2).
3.
Install two mounting brackets (3), two screws (4), and two nuts (5).
4.
Install air tank (10), four washers (7), and four nuts (1).
5.
Connect two tubes (8) to air tank (10).
6.
Install rear platform (WP 0172 00).
7.
Start vehicle and check for leaks (TM 9-2320-303-10).
END OF WORK PACKAGE
0129 00-3/(0129 00-4 blank)
|