|
|
TM 9-2320-303-24-1
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0098 00
f.
Push contacts (4) into insert (5) from rear until seated.
g.
Push grommet (3) down cable leads (1) and over solder wells of contacts (4).
h.
Screw nut (2) onto shell (6) assembly.
3
2
4
5
1
6
3.
Plug Disassembly.
a.
Unscrew nut (8) from shell (13) assembly and slide back on cable leads (7).
b.
Push grommet (9) back on cable leads (7).
c.
Slide coupling nut (10) off shell (13) assembly.
d.
Drive contacts (11) out through rear of insert (12) with pin extractor.
e.
Push insert (12) out through rear of shell (13).
f.
Unsolder cable leads (7) from contacts (11).
10
9
13
7
11
12
8
4.
Plug Assembly.
a.
Strip cable insulation equal to depth of solder wells of contacts (11).
b.
Slide nut (8) over cable leads (7).
c.
Slide grommet (9) over cable leads (7).
d.
Insert cable leads (7) into solder wells of contacts (11) and solder.
e.
Push insert (12) into shell (13) from rear until seated. Groove in insert must be aligned with guide in shell to ensure
proper fit.
f.
Push contacts (11) into insert (12) from rear until seated.
g.
Slide coupling nut (10) onto shell (13) assembly.
h.
Push grommet (9) down cable leads (7) and over solder wells of contacts (11).
i.
Screw nut (8) onto shell (13) assembly.
0098 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |